Dillon GS Plus Force Gauge Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Dillon GS Plus Force Gauge. Dillon GS Plus Force Gauge User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 18
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
GS Series User’s Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 17 18

Podsumowanie treści

Strona 1

GS Series User’s Manual

Strona 2 - Table of Contents

GS series User’s Manual REV 2.1 22/01/12 10 Main Menu Press MENU/ESC key to access the main menu. To move between the option listed on the main m

Strona 3 - Introduction

GS series User’s Manual REV 2.1 22/01/12 11 2) PASS-FAIL the Pass-Fail feature used to set a defined acceptable maximum and minimum forces gap for

Strona 4 - Powering the first time

GS series User’s Manual REV 2.1 22/01/12 12 example LOWER LEVEL = 20 N, UPPER LEVEL = 0 N Load The “OK” LED will ON. Another LED

Strona 5 - Using the GS

GS series User’s Manual REV 2.1 22/01/12 13 Figure 7a Memory Page Press UP and DOWN to change memory page, press and hold to scroll cha

Strona 6 - Basic Functions

GS series User’s Manual REV 2.1 22/01/12 14 A total of overload count % offset of last calibrate % curr

Strona 7

GS series User’s Manual REV 2.1 22/01/12 15 Measurement practice For best measurement accuracy keep the compression/tension forces in line with t

Strona 8

GS series User’s Manual REV 2.1 22/01/12 16 GS Specifications Capacity and Divisions Capacity (N) mN N kN g-f kg-f oz-f lb-f 5 5000 x 2 5 x 0.0

Strona 9

GS series User’s Manual REV 2.1 22/01/12 17 Conversion Factor Unit mN N kN g-f kg-f oz-f lb-f mN 1 0.001 1e-6 101.97e-3 101.97e-6 3.597e-3

Strona 10 - Main Menu

GS series User’s Manual REV 2.1 22/01/12 18 Dillon, a Weigh-Tronix Brand 1000 Armstrong drive Fairmont, Minnesota 56031 Sales (50

Strona 11 - Upper level

GS series User’s Manual REV 2.1 22/01/12 2 Table of Contents Table of Contents…………………………………………………………… 2 Introduction…………………………………………………………………… 3

Strona 12 - Lower level

GS series User’s Manual REV 2.1 22/01/12 3 Introduction Thank you for choosing the Dillon GS series instrument. With correct use and regular re-c

Strona 13

GS series User’s Manual REV 2.1 22/01/12 4 Powering the first time The GS is supplied with a set of 4 Nickel Metal Hydride AA rechargeable batte

Strona 14

GS series User’s Manual REV 2.1 22/01/12 5 Using the GS Fitting Accessories Couple fittings directly to the load cell stem or use an extension rod

Strona 15 - Measurement practice

GS series User’s Manual REV 2.1 22/01/12 6 To power up the gauge press the ON/OFF key. A short self-test runs during which the display will show the

Strona 16 - GS Specifications

GS series User’s Manual REV 2.1 22/01/12 7 A load indicator bar alerts the operator to how much load has been applied to the load sensor. For tensi

Strona 17 - Conversion Factor

GS series User’s Manual REV 2.1 22/01/12 8 Peak-Tension mode Press MODE key until the appeared on the display. The display will show the maxi

Strona 18

GS series User’s Manual REV 2.1 22/01/12 9 Saved reading to memory Any reading can be saved anytime by press MEM/ENTER key. A total of 500 readin

Komentarze do niniejszej Instrukcji

Brak uwag